| 1 | Has a current risk assessment for the fairground operation been completed and briefed to all staff? |
| 2 | Are all ride operators trained, competent and hold a valid ride operation licence? |
| 3 | Is the site layout plan displayed and does it show clear separation between ride areas, public pathways and emergency routes? |
| 4 | Are all public access routes free of slip, trip and obstruction hazards? |
| 5 | Have all rides been inspected by a competent ADIPS‑registered inspector and have valid inspection certificates on site? |
| 6 | Is each ride’s structural frame free of cracks, corrosion or deformation? |
| 7 | Are all moving parts, chains and safety devices on rides lubricated, free of wear and correctly tensioned? |
| 8 | Are emergency stop controls on each ride clearly marked, functional and tested before operation? |
| 9 | Is the ride’s load rating displayed and not exceeded by the number of passengers? |
| 10 | Are passenger restraint systems (bars, belts, safety nets) fitted, undamaged and locked before each ride cycle? |
| 11 | Are ride guard rails and barriers in good condition and positioned to prevent unauthorised entry? |
| 12 | Is the ride’s braking system inspected and functional before each operation? |
| 13 | Are all ride safety signs (maximum load, height restrictions, speed limits) clearly displayed and legible? |
| 14 | Is the ride’s control panel free of loose wires, securely mounted and labelled? |
| 15 | Is the ride’s ROPS/FOPS (if applicable) inspected and in good condition? |
| 16 | Are passenger seats or containers inspected for damage, secure attachment and proper locking? |
| 17 | Is a daily test run of the ride performed by a competent operator before opening to the public? |
| 18 | Are generators installed on stable, level ground and protected from weather exposure? |
| 19 | Are generator fuel stores secured, labelled and away from ignition sources? |
| 20 | Is the generator’s output voltage and frequency within the specifications required for ride electrical systems? |
| 21 | Are all electrical cables and connections for rides and generators inspected for damage and properly earthing? |
| 22 | Are portable electrical tools and equipment used on site PAT‑tested and marked with the current test date? |
| 23 | Are fire extinguishers appropriate to the hazards present, serviced and clearly visible at each ride and generator area? |
| 24 | Are first‑aid kits stocked, accessible and signed‑in by a trained first‑aider on site? |
| 25 | Are all operatives wearing appropriate personal protective equipment such as helmets, high‑visibility clothing and safety footwear? |
| 26 | Is there a documented emergency evacuation procedure posted and communicated to staff and the public? |
| 27 | Is the weather forecast for the day reviewed and are rides stopped in high winds, lightning or heavy rain? |
| 28 | Are all public crowd control barriers and signage in good condition, clearly visible and positioned to prevent unauthorised access to ride areas? |
| 29 | Is emergency lighting functional and illuminated along evacuation routes and near ride exits? |
| 30 | Are ride hydraulic systems inspected for leaks, correct pressure and proper operation before each use? |
| 31 | Is the generator’s exhaust system properly vented and free of blockages? |
| 32 | After each operating day, are rides locked, cleaned and stored or covered as required? |